top of page

We Protect Lives and Property

Panels and Detectors

GST M200

Intelligent Fire Alarm Panel

  • Single loop fire alarm control panel listed by UL Loop capacity 230 intelligent devices

  • 2 Style Y Notification Appliance Circuits (NAC)

  • 3 fixed relay outputs for fire/fault/supervisory

  • Optional GMC connection

  • Walk Test function

  • Positive Alarm Sequence (PAS) per point

  • Programmable from panel keypad

  • Advanced user friendly programming software including ‘Fuzzy Logic’

Technical Specifications

  •  AC Power supply:     120V/60Hz/2A or 220VAC 50Hz/1A     Power cable size minimum 14AWG

  • Operating Environment:     Temperature: 0~+ 40°C     Relative Humidity: 95%

  • Dimension: 406mm x 666mm x 130mm

I-9102(UL)

Intelligent Optical Smoke Detector

  • Aesthetically pleasing low profile design

  • 8 Bit intelligent processor with A/D converter

  • Built in algorithm maps for false alarm rejection

  • Electronically addressed

  • Twin LED for 360o vision

  • Removable optical chamber for easy cleaning and maintenance

Amerex fire extinguisher

Technical Specifications

  • Operating voltage: 24VDC

  • Operating current:

Standby current: 0.8mA

  • Alarm current 2mA

  • Operating Environment:

Temperature: 0 ~ +37.8°C

  • Relative Humidity: 95%

  • Dimensions: Diameter 100mm, Height 50mm

 

I-9103(UL)

Intelligent Dual Heat Detector

  • Fixed Temperature and Rate of Rise Heat Detection

  • Aesthetically pleasing low profile design

  • 8 Bit intelligent processor with A/DconverterElectronically addressed

  • Twin LED for 360o vision

DI-M9204

Technical Specifications

  • Operating voltage: 24VDC

  • Operating current:

Standby current: 0.8mA

  • Alarm current 2mA

  • Detection Angle: <45°

  • Operating Environment:

Temperature: 0 ~ +37.8°C

  • Relative Humidity: 95%

  • Dimensions: Diameter 100mm, Height 45mm

 

Digital Manual Call Point

  • Re-settable (non-breaking glass) via special key

  • Advanced digital communication

  • Electronically addressed

  • Friendly installation and test

  • Wiring before termination

  • Semi-flush mount installation

  • Optional back-box for surface mount

  • Stylish pleasing design

C-9503

Technical Specifications

  • Protection Rating: IP43

  • Operating Voltage: 24VDC

  • Operating Current:

Standby Current 0.6mA
Alarm Current 1.8mA

  • Operating Environment:

Temperature: -10 ~+50°C
Relative Humidity: 95%

  • Application: Indoor use

  • Dimensions: 87.1 x 87.1 x 58 mm

 

Short Circuit Isolator

  • Isolates faulty part of the loop in the event of a short circuit

  • Automatically reset once the fault has been cleared

  • LED status indicator

Technical Specifications

  • Operating Voltage: 24VDC

  • Operating Current:

Monitor Current 3mA
Action Current 15mA

  • Operating Environment:

Temperature: 0 ~ +49°C
Relative Humidity: 93%

  • Dimensions: 120mm x 80mm x 39mm

 

DZ-03(UL)

Detector Base

  •  Common Base for termination and fixing of detectors, compatible for I-9102(UL),

C-9102(UL), I-9103(UL) & C-9103(UL)

  • Non-electronic component

I-M9300

Addressable Input Module

  • Single input module suitable for monitoring switch contact of remote equipment or

  • connecting conventional detectors

  •  Loop power for contact input

  • Used as interface with conventional detectors and additional 24VDC is required

  • Connection mode can be set by handhold programmer (P-9910B)

  • Conventional connection is monitored for cable fault

  • Electronically addressed

  • Two part plug-in construction with base mounted termination allows

  • easy installation and connection

  • Intelligent interface can be addressed and plugged in to base at time of commissioning

Technical Specifications

  • Operating Voltage: 24VDC

  • Operating Current:

Loop
Standby Current 1mA
Action Current 5mA
24VDC
Standby Current <10mA
Action Current <60mA

  • Operating Environment:

Temperature: 0~ +49°C
Relative Humidity: 93%

  • Dimension: 120mm x 80mm x 43mm

I-M9301

Addressable Output Module

  • Single output module

  • Loop powered for dry contact relay output. Additional 24VDC is required for power output

  • Connection mode can be set by handhold programmer (P-9910B)

  • Power output line is monitored for cable fault

  • Electronically addressed

  • Two part plug-in construction with base mounted termination allows

  • easy installation and connection

  • Intelligent interface can be addressed and plugged in to base at time of

commissioning

Technical Specifications

  • Operating Voltage: 24VDC

  • Operating Current:

Loop
Standby Current 1mA
Action Current 3mA
24VDC
Standby Current <5mA
Action Current <20mA

  • Output capacity

Dry contact relay: 2A/24VDC
Power output: 1A/24VDC

  • Operating Environment:

Temperature: 0~ +49°C
Relative Humidity: 93%

  • Dimension: 120mm x 80mm x 43mm

 

For a complete list of panels and detectors please contact us

© 2014 Harris Fire Safety L.T.D

  • b-facebook
  • Twitter Round
  • b-googleplus
bottom of page